With the higher pace of climate change, temperatures are rising each year, resulting in various effects on the thermal status of buildings. This study shows that the application of the two proposed novel constructive improvements allows reducing the value of the linear thermal transmittance of the thermal bridge between 20% and 63.4% and the heating demand between 16.1% and 22.6%. EnergyPlus was used to carry out an analysis of annual energy efficiency indicators of nZEB dwellings in three Spanish cities: Alicante, Barcelona and Madrid. Thermal bridges (traditional construction system and improved systems) have been analyzed through the value of the linear thermal transmittance using THERM software. This paper analyzes this type of thermal bridges and proposes two novel construction improvements that reduce their impact on energy demand, while maintaining traditional façade construction systems. One of the thermal bridges that has the greatest impact on energy demand in residential buildings is the junction of façades with intermediate slabs (slab fronts), which becomes more significant as the number of floors in the building increases. This effect is increased with the introduction of greater thicknesses of thermal insulation required by regulations. Designers do not attach importance to their impact on the energy demand of buildings. mtr file to create a similar version for “metered” outputs.The traditional construction systems of façades in Spain give rise to a large number of thermal bridges. csv file which can be read easily into Excel™. rvi is used with the ReadVarsESO post-processing program and the. In addition to the idf files, usually an. ! Coils: Coil:Cooling:Water, Coil:Heating:Water
! Zonal Equipment: AirTerminal:SingleDuct:VAV:Reheat ! stream to precondition the outside air. HW and ChW coils are used in the outside air ! boiler, electric compression chiller with air cooled condenser. ! HVAC: Standard VAV system with outside air, hot water reheat coils, ! Doors: 2 ea.: Single pane grey, 3mm glass ! 4) Double pane lowE, 6mm lowE glass outside, 6mm air gap, 6mm clear glass ! 3) Double pane clear, 6mm glass, 6mm air gap ! 2) Double pane clear, 3mm glass, 13mm argon gap ! Windows: 4 ea.: 1) Double pane clear, 3mm glass, 13mm air gap
! Interzone Surfaces: 6 interzone surfaces (see diagram) The infiltration is 0.25 air changes per hour. ! Internal gains description: lighting is 1.5 watts/ft2, office equip is 1.0 watts/ft2. ! The building is oriented 30 degrees east of north. ! The south wall and door have overhangs. The window to wall ratio is approxomately 0.29.
Example of energyplus idf file for hvac simulation windows#
! The windows are of various single and double pane construction with 3mm and 6mm glass and either 6mm or The roof is a gravel built up roof with R-3 mineral board insulation and plywood sheathing. The walls are woodshingle over plywood, R11 insulation, ! The south facing glass is shaded by overhangs. There are windows on all 4 facades the south and north facades have glass doors. There is a 2 foot high return plenum: the overall building height is 5 zones - 4 exterior, 1 interior, zone height 8 feet.
! Building: Single floor rectangular building 100 ft x 50 ft. ! Run Control: Zone and System sizing with weather file run control (no design days run) ! Run Period (Weather File): Winter 1/14, Summer 7/7, CHICAGO_IL_USA TMY2-94846 ! CHICAGO_IL_USA Annual Cooling 1% Design Conditions, MaxDB= 31.5☌ MCWB= 23.0☌ ! Design Days: CHICAGO_IL_USA Annual Heating 99% Design Conditions DB, MaxDB= -17.3☌ ! Run Control executes the run periods using the weather file ! Simulation Location/Run: CHICAGO_IL_USA TMY2-94846, 2 design days, 2 run periods, ! outside air stream controlled to preheat and precool setpoints. ! Highlights: Electric chiller with air cooled condenser autosized preheating and precooling water coils in the ! Basic file description: 1 story building divided into 4 exterior and one interior conditioned zones and return plenum.